Draeger Tube,Triethylamine 5/A 5-60ppm, Box of 10
DRAEGER SAFETY INC.
/ Model #6718401
Details
Draeger Tube - Triethylamine 5/a
Order No. 67 18 401
Application Range | |
Standard Measuring Range | 5 to 60 ppm |
Number of Strokes n: | 5 |
Time for Measurement: | approx. 3 minutes |
Standard Deviation: | ± 10 to 15% |
Color Change: | yellow to blue |
Ambient Operating Conditions | |
Temperature: | 10 to 40° C ~ 50 to 104° F |
Absolute Humidity: | 5 to 12 mg H2O /L |
Reaction Principle | |
(C2H5)3N + acid → blue reaction product | |
Cross Sensitivity | |
Other basic substances such as organic amines and ammonia are indicated, but with different sensitivities. |