Draeger Tube, Chloroprene 5/A 5-90ppm, Box of 10
DRAEGER SAFETY INC.
/ Model #6718901
Details
Draeger Tube - Chloroprene 5/a
Order No. 67 18 901
Application Range | |
Standard Measuring Range | 5 to 60 ppm |
Number of Strokes n: | 3 + 3 desorption strokes in clean air |
Time for Measurement: | approx. 3 minutes |
Standard Deviation: | ± 10 to 15% |
Color Change: | violet to yellow brown |
Ambient Operating Conditions | |
Temperature: | 10 to 30° C ~ 50 to 86° F |
Absolute Humidity: | 3 to 15 mg H2O / L |
Reaction Principle | |
CH2=CH-CCI=CH2 + MnO4- MnVI + various oxidation products | |
Cross Sensitivity | |
Many other organic compounds with C=C double bonds are indicated as well, but with different sensitivities. It is impossible to differentiate them. It is impossible to measure chloroprene in the presence of dialkyl sulfides. |