Draeger Tube, Box of 10 Methylene Chloride
DRAEGER SAFETY INC.
/ Model #8103591
Details
Draeger Tube - Methylene Chloride 20/a
Order No. 81 03 591
Application Range | |
Standard Measuring Range | 20 to 200 ppm |
Number of Strokes n: | 8 |
Time for Measurement: | 7 |
Standard Deviation: | ± 15 to 25% |
Color Change: | yellow to red |
Ambient Operating Conditions | |
Temperature: | 17 to 30° C ~ 62.6 to 86° F At 25° C to 30° C (77 to 86° F) multiply the reading with the factor 0.6 |
Absolute Humidity: | 3 to 25 mg H2O / L |
Reaction Principle | |
a) CH2CI2 + chromate → CI2 b) CI2 + amine → red reaction product |
|
Cross Sensitivity | |
100 ppm n-octane and 300 ppm carbon monoxide do not interfere the reading. In case of concentrations > 100 ppm n-octane, methylene chloride is not indicated. Other chlorinated hydrocarbons will be indicated. |