Draeger Tube - Halogenated Hydrocarbons 100/a
Order No. 81 01 601
Application Range | |
Standard Measuring Range | 200 to 2,600 ppm R 113/R 114 100 to 1,400 ppm R 11 200 to 2,800 ppm R 22 1,000 to 4,000 ppm R 134a (on request) The indication is in mm and must be compared to the calibration data sheets |
Number of Strokes n: | 3 |
Time for Measurement: | approx. 1 minutes |
Standard Deviation: | ± 30% |
Color Change: | blue to yellow / greyish green |
Ambient Operating Conditions | |
Temperature: | 0 to 40° C ~ 32 to 104° F |
Absolute Humidity: | 1 to 15 mg H2O / L |
Reaction Principle | |
a) R113 [pyrolysis] HCI b) HCI + pH indicator yellow reaction product |
|
Cross Sensitivity | |
Other halogenated hydrocarbons, free halogens and hydrogens halides are also indicated, however, with differing sensitivity. Perchloroethylene is indicated with the same sensitivity as R113. | |
Additional Information | |
The tubes become very warm during the measurement. Therefore, these tubes should not be used in potentially combustible atmospheres. A combustible gas monitor should be used to qualify any questionable area before conducting a measurement with one of these tubes. |